The Emergency Alert app turns your screens into digital signage emergency alerts. Pick the alert, such as Evacuate, Fire or Lockdown, and the screen shows the severity, a pictogram, a short headline and numbered instructions in the screen’s language. For alerts where people must leave, a green exit sign with an arrow points each screen’s viewers to the way out.
The app runs on the screen without an internet connection, in landscape and portrait, and in any layer size.

Warning: Screen content doesn’t replace a fire alarm or a public address (PA) system. Use the app alongside them, never instead of them.
With the Emergency Alert app you can:
- Show 12 ready-made alerts, each with standard wording and instructions in 18 languages.
- Add your own headline, up to five instructions, an assembly point and a contact.
- Point a green exit sign towards the exit, with a direction set per screen by a tag, so one alert serves every screen in the building.
- Show the standard wording again in a second language, under the first.
- Prepare alerts in advance and switch screens to them in an emergency.
Note: The Emergency Alert app isn’t offered in video wall playlists.
On this page
- Add the Emergency Alert app
- Choose the alert (Content): alert, headline, severity, instructions and language
- Point the exit arrow: the default direction and each screen’s own direction
- Set the size (Appearance)
- Advanced settings: time, attention border, arrow movement, logo, numerals and time zone
- What the screen shows
- Common tasks:
- Troubleshooting
How to Add the Emergency Alert App
Open the playlist, then click the layer. See Playlist Media Management.
If the layer is empty, the content apps open. If it already has media, click Add New.
Type
Emergencyin Search Apps, then click Emergency Alert.

The Emergency Alert editor opens. It has three tabs: Content, Appearance and Advanced. The Live preview shows your changes as you make them.
On the Content tab, choose the alert and its instructions. See Choose the alert. Click Next.
On the Appearance tab, set the size. See Set the size. Click Next.
On the Advanced tab, change any other settings. See Advanced settings.
Click Add.

- Click Publish changes to send the playlist to your screens.
Every setting has a ready-to-use default. A new item shows an Evacuate alert in English, with the standard instructions and an exit arrow pointing ahead.
To see a larger preview, click Expand preview. To change the settings later, click Edit next to the item in the layer.
Choose the Alert (Content)
The Content tab has three cards: Alert, Instructions and Language.
Alert

- Alert: the kind of alert. Each alert has its own pictogram, standard headline, standard instructions and severity:
Alert Severity Exit arrow Evacuate Emergency Yes Fire Emergency Yes Lockdown Emergency No Shelter in place Emergency No Severe weather Warning No Medical emergency Warning No Gas leak Emergency Yes Earthquake Emergency No Hold (stay in rooms) Warning No Test of the display system Information No All clear Information No Custom (your own headline) Warning Yes
Headline (optional): your own headline, up to 60 characters. Leave it empty to show the standard headline for the alert, in the screen’s language. Keep it to 8 words or fewer, so people can read it in a few seconds.
Severity: the colour and the word in the top bar:
- From the alert: the severity in the preceding table. Recommended.
- Emergency (red), Warning (amber) or Information (blue): a severity of your own choice.
An All clear shown as information is green. The severity is always written in the top bar too, so it doesn’t rely on colour alone.
Instructions

- Instructions (optional): up to five short instructions, one per line. Click the pencil icon to open List’s Items, type an instruction, click + to add the next one, then click Done. Leave the list empty to show the standard instructions for the alert. The screen numbers the instructions for you, so you don’t need to type “1.” or “-”.
- Assembly point (optional): where people gather, for example
Car park B. It shows with a pin icon, up to 60 characters. - Contact (optional): who to call, for example
Security, ext. 5555. It shows with a phone icon, up to 60 characters. - Exit arrow: the direction of the exit for screens without their own direction. See Point the exit arrow.
Language
Language: the language of the standard headline, the instructions, the severity word and the word “Exit”. Choose from 18 languages, including Arabic, which shows right to left.
Second language: shows the standard wording again in a second language, under the first and in smaller text. Choose None to show one language. Text you typed yourself isn’t repeated, because it’s in one language only. The exit sign always shows the word “Exit” in both languages.
Point the Exit Arrow
The exit arrow always points to the exit. It shows as a green exit sign of its own, with the running person pictogram and the word “Exit”, away from the alert’s pictogram. That way, nobody reads the arrow as pointing towards the fire or the hazard.
The arrow shows only for alerts where people leave: Evacuate, Fire, Gas leak and Custom. Lockdown, shelter in place, hold, earthquake, medical emergency, severe weather, test and all clear alerts never show it, because an arrow to the exit could send people the wrong way.
Each screen hangs in a different place, so the exit is in a different direction from each one. The direction can come from two places:
- The screen’s own tag: a tag on the screen named
exit_direction. It wins over the setting. See Give each screen its exit direction. - The Exit arrow setting: the direction for every screen without the tag. The default is Ahead (↑).
With the tag, one alert in one playlist points the right way on every screen.
Choose the direction
The direction is as seen by someone standing in front of the screen and facing it.

| Exit arrow setting | Tag value | Where the exit is |
|---|---|---|
| None | none | No arrow |
| Ahead (↑) | 0 | Straight ahead, past the screen |
| Ahead and right (↗) | 45 | Ahead, to the right |
| Right (→) | 90 | To the right |
| Back and right (↘) | 135 | Behind the viewer, to the right |
| Back or down (↓) | 180 | Behind the viewer, or down the stairs |
| Back and left (↙) | 225 | Behind the viewer, to the left |
| Left (←) | 270 | To the left |
| Ahead and left (↖) | 315 | Ahead, to the left |
The arrow is a direction in the building, so it isn’t mirrored for right-to-left languages such as Arabic.
Note: The Live preview in the editor has no screen tags, so it always shows the Exit arrow setting. Each screen with an
exit_directiontag shows its own direction.
Arrow movement
When Move the arrow is on, the arrow glides a little towards the exit and back once every 2 seconds, so it draws the eye. It’s movement only: the arrow never flashes or changes brightness. Turn it off on the Advanced tab. See Advanced settings.
Set the Size (Appearance)

- Size (%): makes the whole alert larger or smaller, from 80% to 140%. Leave Enable on, then set the size with the slider or the box next to it. The default is 100%.
The app always fits the alert inside the layer. When the text is long, it gets smaller to fit. When even the smallest size is too large, the app leaves out the least important parts first. See What the screen shows.
Advanced Settings

Display
- Show the time: shows the current time, small, in the top bar, so people can see the screen is live. On by default.
- Attention:
- Still (recommended): the coloured border stays still.
- Slow pulse of the border (never flashes): the border fades slowly between full and faint brightness, once every 2 seconds.
- Move the arrow: the exit arrow glides towards the exit and back. On by default. See Arrow movement.
- Logo (optional): your logo, small, in the top bar next to the time. Choose it from Media Assets. The logo doesn’t show in thin strips and small layers.
Time zone & numerals
- Numerals: 0123 (Western digits) or ٠١٢٣ (Arabic-Indic digits), for the time and the instruction numbers.
- Time zone: The screen’s time zone, or A fixed time zone for the time shown in the top bar.
- Timezone: the time zone used when Time zone is A fixed time zone.
What the Screen Shows
The colour of the top bar, the border and the pictogram show the severity, and the top bar spells it out: Emergency on red, Warning on amber and Information on blue. An all clear is green.

The app chooses the layout from the shape of the layer:
- Landscape: the alert’s pictogram at the start, the headline and instructions in the middle, and the exit sign at the far end.
- Portrait: the pictogram on top, then the text, then the exit sign.
- Thin strip, such as a footer: one line with the severity, the headline and a green exit chip.
- Small layer, such as a corner zone: the severity, the first words of the headline and a green exit chip.

When a layer is too small for everything, the app leaves out parts in this order, so the alert stays readable:
- The instructions in the second language.
- The contact.
- The assembly point.
- The instructions.
- The headline in the second language.
The severity, the pictogram, the headline and the exit sign always stay.
On a screen that shows the alert for hours, the whole alert moves by a few pixels every 10 minutes to protect the screen from burn-in.
Common Tasks
How to prepare emergency playlists in advance
In an emergency there’s no time to build content, so prepare it before you need it.
- Create a playlist named, for example, “Emergency – Evacuate”. See Playlists.
- Add an Emergency Alert item with the Evacuate alert, your assembly point and your contact.
- Repeat for the other alerts you may need, such as Fire, Lockdown and All clear, each in its own playlist.
- Make a horizontal and a vertical version of each playlist if you have screens in both orientations. A horizontal screen only lists horizontal playlists, and a vertical screen only lists vertical playlists.
- Give each screen its exit direction. See Give each screen its exit direction.
- Test the playlists with the Test of the display system alert, so nobody mistakes the test for a real alert.
How to switch screens to an alert
- Go to Screens.
- Set each screen’s content to the alert’s playlist. See Set screen content.
- Publish the screens. To publish several screens in one step, select them and click Publish. See Publish to selected screens.
When the emergency is over, switch the screens to your All clear playlist, then back to their usual content.
How to give each screen its exit direction
Add a tag named exit_direction to each screen, with the direction after a colon.
- Stand in front of the screen, facing it, and note the direction of the nearest safe exit. Use the table in Choose the direction.
- Go to Screens.
- Select the screens that share the same exit direction.
- Click Tags, then Add.
- Type the tag with its value, for example
exit_direction:90for an exit to the right, and press Enter. - Click Save.
- Publish the screens. Screens pick up tag changes on their next publish.
For more on adding tags to screens, see Add or remove tags on selected screens and Tag Manager.
- Write the tag with a colon and no spaces:
exit_direction:90. A tag without a colon, such asexit_directionalone, has no value, so the screen uses the Exit arrow setting. - To show no arrow on a screen, for example a screen next to the exit, use
exit_direction:none. - Numbers between the directions are rounded to the nearest 45 degrees. You can also use the words
ahead,right,back,downandleft, for exampleexit_direction:left. - To change a screen’s direction, remove its old
exit_directiontag and add the new one.
How to show an alert in two languages
- On the Content tab, set Language to the main language of your visitors.
- Set Second language to the other language.
- Leave Headline (optional) and Instructions (optional) empty, so both languages show the standard wording.
If you type your own headline or instructions, they show in one language only, and the second language shows only the standard wording for the parts you left empty.
Troubleshooting
The exit arrow doesn’t show.
Check these in order:
- Check the alert. Only Evacuate, Fire, Gas leak and Custom alerts show the arrow.
- Check Exit arrow on the Content tab. If it’s None, only screens with an
exit_directiontag show an arrow. Items added before the default changed to Ahead (↑) may still be set to None. - Check the screen’s tags. A tag of
exit_direction:nonehides the arrow on that screen.
The arrow points the wrong way on one screen.
- The direction is as seen by someone facing the screen. Check the screen’s
exit_directiontag against the table in Choose the direction. - The screen’s tag wins over the Exit arrow setting. To use the setting, remove the tag from the screen and publish it.
- Check that the screen has only one
exit_directiontag.
The screen ignores its exit_direction tag.
- Write the tag as
exit_direction:90, with a colon and no spaces. - Publish the screen after you change its tags.
- If the screen has many tags, the app may not receive all of them. Remove the tags the screen no longer needs.
Some instructions or the assembly point are missing.
The layer is too small to show everything at a readable size, so the app left out the least important parts. See What the screen shows. Give the app a larger layer, shorten your instructions, or set Second language to None.
The time in the top bar is wrong.
With Time zone set to The screen’s time zone, the time comes from the screen. Check the screen’s location or time zone. See Screen timezone. To show the time of one place on every screen, set Time zone to A fixed time zone and choose the Timezone.